Product catalog

From generation to end-users

Browse equipment for every part of the power chain. Add the items you need to your quote request, and our engineers will reply with pricing, availability and lead times.

Products

44 products

Gemini

Gemini CT,PT

Gemini's OIP Insulated Instrument Transformers, designed for outdoor use, offer total reliability. Our range includes OIP Current Transformers (12 kV to 145 kV) meeting IEC standards.

  • Generation
  • Substation
Details for Gemini CT,PT

INAEL

Surge Arresters

Station Class Polymeric Surge Arrester. Offer unrivaled performance and optimum cost. Ratings up to 132kV, 10kA. Distribution Class Surge Arrester. Metal-oxide, ratings up to 42kV. Nominal discharge current: 10kA, 60Hz.

  • Generation
  • Transmission
  • Substation
  • +2 more
Details for Surge Arresters

EKOS

36kV GIS Switchgear

A Ring Main Unit (RMU) is a totally sealed, gas-insulated (SF6 filled) compact switchgear unit. Available in compact and modular type.

  • Generation
  • Substation
  • End-Users / Consumers
Details for 36kV GIS Switchgear

SOJO

24kV Solid Insulated Switchgear

SF6-free solid insulated switchgear (SVI-12/24). Ring main units for primary and secondary power distribution: 12kV (630A/1250A) and 24kV (630A). Vacuum switching sealed in epoxy resin (IP67), maintenance-free with a 30-year lifespan. Modular and extensible on both sides, with remote monitoring through DTU/RTU. Complies with IEC 62271-200.

  • Substation
  • Distribution / Electric Utility
  • End-Users / Consumers
Details for 24kV Solid Insulated Switchgear

Thytronic

OverCurrent Relay

The NA011 feeder protection relay suits radial networks, handling long feeders in grounded systems and shorter ones in ungrounded setups to prevent capacitive fault tripping.

  • Generation
  • Substation
Details for OverCurrent Relay

Thytronic

Over/Under Voltage Relay

The Thytronic NV10B relay provides voltage protection (undervoltage 27, overvoltage 59 and residual overvoltage 59N) for HV, MV and LV networks and electrical machines, for system decoupling, load shedding and loss of main.

  • Generation
  • Substation
  • End-Users / Consumers
Details for Over/Under Voltage Relay

ESIT

Current and Potential Transformers

Indoor and outdoor CTs and PTs, 7.2kV to 36kV. Cast resin current transformers (CTM, CTB, CTD and CTSG for indoor; CTH for outdoor) and voltage transformers (VTM, VTB and VTBF for indoor; VTH and 2VTH for outdoor), plus oil-type CTY and VTY for 36kV outdoor. Outdoor CTH available in 15kV - 26kV with ERC Sticker and test report. Also low-voltage toroidal and ring-type CTs.

  • Generation
  • Substation
  • Distribution / Electric Utility
  • +1 more
Details for Current and Potential Transformers

ALCE

Current and Potential Transformers

Indoor and outdoor CTs and PTs, 12kV to 36kV. Support-type cast resin current transformers AB12 (up to 2500A), AB24 (up to 4000A), AB36 (up to 3000A) and AK24/AK36. Single and double pole voltage transformers for indoor (VB, VK, 2VB, VBF with fuse) and outdoor (VH24/VH36, 2VH24/2VH36) use. Available with ERC Sticker and test report. Also low-voltage cable-type (KAT) and split-core (SAA) CTs.

  • Generation
  • Substation
  • Distribution / Electric Utility
  • +1 more
Details for Current and Potential Transformers

Lindsey

Emergency Restoration System

Lindsey ERS structures quickly bypass transmission towers at any voltage and terrain. Easily installed by hand, crane, or helicopter, they are robust enough for temporary or long-term use, with some in service for over a decade.

  • Transmission
Details for Emergency Restoration System

HartBR

Rocket-1 Single-Phase Recloser

Smart single-phase recloser that installs in a standard fuse cutout. 15.5kV and 27kV/38kV-M versions, 200A, vacuum interruption in a polymer body. Self-powered with no batteries, built-in GPS for fault location, IoT radio (LoRa/NB-IoT) for SCADA and Bluetooth app setup. Works as a single- or three-phase recloser, switch or sectionalizer. Tested to IEEE C37.60-2019.

  • Distribution / Electric Utility
Details for Rocket-1 Single-Phase Recloser

Italweber / Inter-Teknik

Power Fuse

MV Current-Limiting Fuses. Italweber and Inter-Teknik back-up HV HRC fuse-links for indoor and outdoor use, from 6kV to 36kV. Italweber FMT fuses rated 6A-200A; breaking capacity up to 63kA (Inter-Teknik, KEMA verified). With striker pin trip indicator. Protects transformers, motors, cables and overhead lines, voltage transformers and capacitor banks.

  • Substation
  • End-Users / Consumers
Details for Power Fuse

Pomanique

Solid Insulated Vacuum Recloser

Pomanique’s GX-Series switch delivers reliable, cost-effective automation for up to 38 kV circuits. It features durable vacuum interrupters, solid insulation, and a magnetic actuator for lifetime performance. Resistant to UV, moisture, and contamination, it offers precise, programmable electronic controls

  • End-Users / Consumers
Details for Solid Insulated Vacuum Recloser

Driescher

Load Break Switch

Available up to 38.5kV, 60Hz. Current rated up to 1250A (630A at 38.5kV). Able to perform on-load breaking, Has anti-single phasing mechanism.

  • End-Users / Consumers
Details for Load Break Switch

Sigma

Air Circuit Breaker

Fixed (SFA) and drawable (SDA) types, 3 or 4 poles. Rating from 630A to 6300A (5000A and 6300A drawable only), 415V AC. Short circuit breaking capacity up to 100kA. Electronic trip unit, manual or motorized. Wide range of accessories. Compact dimensions.

  • End-Users / Consumers
Details for Air Circuit Breaker

Sigma

Miniature Circuit Breaker

Breaking capacity 4.5kA, 6kA, 10kA and 15kA. Rated current from 1A to 125A, curves B, C and D. 1-2-3-4 poles. 10kA DC types (6A to 125A) for DC applications. Comply with EN-60898-1 (15kA types: EN-60947-2).

  • End-Users / Consumers
Details for Miniature Circuit Breaker

Sigma

Moulded Case Circuit Breaker

Ratings from 16A to 2000A. Available in 1-2-3-4 poles. Short circuit breaking capacity up to 150kA. Thermal-magnetic (fixed or adjustable) and electronic trip units. Wide range of accessories. Complies with EN-60947-2

  • End-Users / Consumers
Details for Moulded Case Circuit Breaker

Montrelec

ATS Controller

Intelligent dual-source ATS controller for all types of transfer switches: Breakers, Solenoid, Contactor and Change Over Switches. Monitors both sources (3-phase voltage, frequency and phase sequence), with genset start/stop, scheduled test runs, load shedding, event log and RS485 Modbus remote monitoring. LCD display, panel mounting, IP55 with gasket.

  • End-Users / Consumers
Details for ATS Controller

I-Switch

ATS Solenoid Type

Solenoid-operated automatic transfer switch for two power sources (utility, generator or battery). Electromagnetic drive with electrical and mechanical interlocking, for up to 660V AC 50/60Hz or 250V DC, with fast transfer of 80ms or less. 4-pole, rated 125A, 250A, 400A, 630A, 800A, 1000A, 1600A and 2000A.

  • End-Users / Consumers
Details for ATS Solenoid Type

Lovato

ATS Controller ATL610

Automatic transfer switch controller (144x144mm) for 2 power sources, with graphic LCD and optical port. Auxiliary supply 110–240VAC and 12/24VDC. 6 inputs, 7 outputs, expandable via EXP modules (RS485, Ethernet and more).

  • End-Users / Consumers
Details for ATS Controller ATL610

Lovato

ATS Controller ATL500

Automatic transfer switch controller (144x144mm) for 2 power sources, with NFC and synoptic display. Self-supplied from the 110–240VAC lines (no DC supply). 2 inputs, 3 outputs.

  • End-Users / Consumers
Details for ATS Controller ATL500

Contactplasma

CKS Transfer Switch

Current Ratings from 125A-1600A. Available in 3P or 4P application. Rated insulation voltage 1000V AC, operational ratings up to 690V AC. For 1P2W, 3P3W, 3P4W systems. With quick make and break operation

  • End-Users / Consumers
Details for CKS Transfer Switch

Contactplasma

CNP Transfer Switch

Current Ratings from 2500A-7000A. Available in 3P or 4P application. Rated insulation voltage 1000V AC, operational ratings at 500V AC. For 1P2W, 3P3W, 3P4W systems. With quick make and break operation.

  • End-Users / Consumers
Details for CNP Transfer Switch

Contactplasma

CMV Transfer Switch

Motor-driven change-over switch, Current Ratings from 125A-7000A. Available in 3P or 4P application. Rated insulation voltage 1000V AC, operational ratings at 500V AC. For 1P2W, 3P3W, 3P4W systems. With electronic control card and I-0-II positions.

  • End-Users / Consumers
Details for CMV Transfer Switch

Contactplasma

CKM Transfer Switch

Motor-driven change-over switch. Current Ratings from 125A-1600A. Available in 3, 4, 6 or 8 poles. Rated insulation voltage 1000V AC, operational ratings up to 690V AC. Motor 220-240V AC (24V DC on request), change-over time 4-5 s, with manual handle operation.

  • End-Users / Consumers
Details for CKM Transfer Switch

Linkwell

Dehumidifier

Compact. Suitable for switchgear. Has strong ability of dehumidification (10 or 22 ml/h for 1 or 2 m³ cabinets). Power Source: AC/DC 110-220V ±10%; DC 48V ±10%; DC 24V ±10%.

  • Switchgear Accessories
Details for Dehumidifier

Linkwell

Hygrostat

Mechanical hygrostat (MFR 012). Relative Humidity Range 35%-95%. Changeover contact, no supply voltage needed. DIN rail mounting. Service Life: 50,000 cycles.

  • Switchgear Accessories
Details for Hygrostat

Linkwell

Fan and Filters

High-performance fan and filter units (FK55 / LK66 series), available in 4x4, 6x6, and 8x8 inches with airflow from 24 to 120m³/h. 230V AC, 115V AC or 24V DC, IP54. Designed for optimal ventilation in Data Cabinets and more, it pairs with an exit filter for efficient cooling of valuable equipment.

  • Switchgear Accessories
Details for Fan and Filters

Linkwell

Thermostat

2-pole terminal, clamping torque. Service life 100,000 cycles. High Switching Performance Simple to Mount.

  • Switchgear Accessories
Details for Thermostat

Linkwell

Panel Heaters

Compact High Performance fan heaters with temperature safety cut-out. 100W to 400W, 230V or 120V AC. High air through flow. DIN rail mounting.

  • Switchgear Accessories
Details for Panel Heaters

Yongsung

Test Terminal Block

CTT and PTT, 3P or 4P, AC 250V 10A. CTT is the Circuit Opening Prevention Type for Current Transformer testing; PTT for Potential Transformer testing.

  • Switchgear Accessories
Details for Test Terminal Block

Italweber

NH Fuses

High Protection against short circuit. gG and aM NH fuse-links, sizes 00C to 3 (6A up to 630A), 500V/690V, breaking capacity up to 120kA. For use in NH fuse bases or fuse switch-disconnectors.

  • Switchgear Accessories
Details for NH Fuses

Montrelec

JCO Control Fuse

High Protection against short circuit Five Sizes. Available from 000 to 3 (100A up to 630A) Din Rail or Base Mounting

  • Switchgear Accessories
Details for JCO Control Fuse